Domekt R 450 V is a compact ventilation unit with vertical connection and heat recovery for ventilation of residential areas. The maximum air capacity of the R 450 V is 472 m³/h, which is enough for a room of up to 200 m² with a ceiling height of up to 2.6 m. The installation dimensions are only 680x535 mm, and the maximum power consumption of the EC fan is 170 W.
Domekt R 450 V is equipped with a rotary heat exchanger (recuperator), which allows maximum saving of electrical energy. The rotary recuperator operates on the basis of thermal energy accumulation. A rotating aluminum cylinder with channels heats up when warm air passes through it, and when cold outside air passes through, it is heated by stored energy. For example, if the air taken in from outside is -20.0°C and the air removed from the room is +22.0°C, the temperature of the fresh supply air will be +16°C.
Non-freezing efficient heat exchanger
The rotary heat exchanger maintains high performance even at an ambient temperature of -20°C, since under normal conditions it is not subject to freezing. Therefore, the installation can be operated without using a preheater. In winter, the air entering the room is partially humidified, creating more comfortable conditions. Condensation does not form, drainage is not required, and installation of the device is simplified.
Air humidity balance
When choosing a rotor with a special hygroscopic coating, the ventilation unit will provide even more effective control over the microclimate in the room - in winter it will dry out the air less, and in summer it will remove excess moisture, thereby reducing the need for air conditioning. This ensures maximum comfort at minimal cost.
Reliability and durability
The housings of Domekt units are made of galvanized steel, which is additionally powder coated. The fan motors are protected from moisture and dust and use durable bearings.
Low noise level
Domekt R units use perfectly balanced fans of special geometry; mineral wool is used as sound insulation for the unit casing. All this ensures a minimum level of noise entering the environment. The noise level entering the duct system is reduced by selecting suitable silencers.
Energy saving
The Domekt R series uses only the most efficient electronically commutated (EC) fans, high-performance rotary heat exchangers, air filters with increased filtration area and intelligent automation, which can significantly reduce operating costs and at the same time maintain a comfortable microclimate.